We've Done Our Homework
Chalkboard-Homework-Ad-for-AJ-200905.gif
 
Thanks for responding to our ad in ASHRAE Journal's 2009 issue.  Please read on; below we've provided additional information and links covering all points in our ad.
 

Desert Aire's TotalAire™ and VeritcalAire units address the first five major bullets listed in the ad above including:

  • DOAS units deliver dry, 100% outdoor air
  • Units eliminate conditions for damaging mold
  • Energy efficient systems save money
  • Accurate temperature control
  • Water-source heat pump available
 
TotalAireTM

TotalAireTM dehumidifiers are deisgned specifically for 100% outdoor air.  They are are capable of handling high moisture loads due to a specially designed evaporator coil.  They are also configured for the easy addition of other components needed for a complete HVAC solution.  Here are some quick facts about TotalAireTM.

  • Controls temperature within ±2.0°F
  • Includes enthalpy wheel option for energy efficiency in all modes-dehumidification, heating and cooling
  • Evaporative coils have raised lance fins, rifled tubes to maximize moisture removal with significant MRE's
  • Reduces mold and mildew problems by eliminating their primary food source, moisture
  • Single point power connection for all units
  • Click Here to view or download the full TotalAireTM brochure


VerticalAireTM
VerticalAireTM dehumidifiers are based off the TotalAireTM product line.  They are designed to address all critical IAQ and 100% outdoor air applications while delivering accurate leaving air temperatures.  VerticalAireTM units provide an IAQ solution for applications with limited space for HVAC equipment.  Here are some quick facts about VerticalAireTM.
  • Controls temperature within ±2.0°F
  • Indoor system
  • Reduces mold and mildew problems by eliminating their primary food source, moisture
  • Small footprint to fit tight mechanical rooms
  • 4- to 15-ton units fit through 36" door
  • Click Here to view or download the full VerticalAireTM brochure

Q-PumpTM 

Q-PumpTM is Desert Aire's 100% outdoor air, water source, non-reversing heat pump which can be integrated into geothermal loops as well as water loops.  Here are some quick facts about Q-Pump.
  • TotalAireTM and VerticalAireTM compatible
  • Integrates into geothermal loops or water loops
  • Heating COPs of 6+
  • Cooling EERs of 14+
  • Click Here to view or download TB-21 "Heat Pump Design for 100% Outdoor Air Systems"
  • Click Here for complete diagrams and details about Q-PumpTM
  • Click Here to watch a video featuring Desert Aire's President, Keith Coursin, explain the Q-Pump
 
Case History
North Carolina Central University used Desert Aire units to dehumidify a dormitory that was literally unlivable due to mold.  To find out how NCCU combatted their mold problem, read their story below or click here to download a PDF of this article.
 
 
Profile
  • Project: North Carolina Central University
  • Application: Dormitory Dehumidification
  • Desert Aire Units: Four (4) TotalAire™ 46-Ton Systems
 
Customer's Battle

It’s the beginning of the 2003-2004 school year at North Carolina Central University (NCCU) in Durham, NC and the college has come alive with activity. Returning students are eager to get back to class. New students are excited to start their college life on campus.

However, shortly after starting the new school year, students and administrative staff noticed mold and mildew developing throughout two dormitories. The problem even became public and was reported in some local newspapers. Without hesitation, the college moved the students out of the dorms and into area hotels to avoid any health risks.

NCCU couldn’t afford exposing students to the mold. On the other hand, it didn’t want to close its dorms either. In need of a solution, the college called upon Herb Stanford, an engineer from Stanford-White Engineering. He soon assessed that moisture was a contributing factor to the mold and mildew. Having worked with Desert Aire on previous dehumidification projects, Herb called his Desert Aire rep in the area.

 
 Desert Aire Strategy

The rep saw right away that this was a classic IAQ problem; the customer needed to get the dewpoint down as low as possible. There was no alternative. The job called for TotalAire™, which is exactly what was sized up for both buildings. Each dorm was fitted with two TotalAire™ 46-ton units with remote condensers.

After some routine troubleshooting and fine-tuning of the controls on the systems, the units were up and running by the end of the first semester. By February of the second semester, the mold and mildew problems had been mitigated allowing the evacuated students to return.

 
Mission Accomplished - Debriefing
The key to the success at NCCU’s dorms was that the TotalAire™ units dramatically reduced the moisture load. The customer was absolutely impressed with TotalAire™’s ability to supply air at 48°F dewpoint and that they were able to solve an emergency design problem with an emergency purchase.
 
 
Find a Desert Aire Sales Representative Nearest You 
To locate and contact your local Desert Aire sales representative, click here.
 
International Sales Assistance
If you would like to find a Desert Aire representative and are outside the United States and Canada, or have any other questions regarding Desert Aire, please e-mail: This e-mail address is being protected from spam bots, you need JavaScript enabled to view it
 
Are You an Engineer?
We encourage all engineers to become registered users on our website.  As a registered user, you can access additional information such as unit dimensional sheets to help you size your application.  You're also able to order hard copies of Desert Aire's literature as a registered engineer.

To log in or register, please click here.